UC+ Integratie Mitel 3300
MitelĀ 3300
Connection: | Proprietary (MiTAI) | ![]() |
Driver required: | Included | |
Firewall ports required: | ICMP Ping TCP: 8000 and 8001 | |
Firmware version required: (for new installations) |
7.0 or later | |
Other requirements: | A license is required for to be purchased (Mitel part number 53001331) for continued use of the MiTAI interface | |
Directory download: | Extensions, agents, and trunks |
Architecture
The Mitel 3300 connects onto the LAN via the RJ45 socket on the front of the PBX. The local IP address and other network settings are set through the HTML-based programming interface
Server Plus Installation Notes
To perform an installation you will need the IP address of the PBX and the system username and password. PLEASE NOTE: these are NOT the logins that are used for the HTML interface. They are the logins from the telnet interface. If in doubt, leave these fields blank to use the defaults
Advisories
The Attendant Console and the 5550 console are not supported as they cannot be monitored. Handsets without speakerphones (including 5001, 5005, 5201, 5207, analog) do not provide a full range of handset control. Blind transfer is not specifically supported by Mitel. It is performed as consultation followed by transfer on ringing. Several handset modes are possible. The modes that have been tested are: Voice set, Keyline, Multicall, Multiline. Multicall and Multiline cannot be used on the same handset at the same time